EC V8 axial and centrifugal fans
Our ventilation and cooling solutions for data centers
Thermal management is a major challenge in data centers because servers, network equipment, and storage systems generate a significant amount of heat. Efficient, energy-saving ventilation is essential to ensure the reliability of installations, optimize power consumption, and extend the life of equipment. Our 350 and 400 mm diameter axial fans and our 250 and 280 mm diameter centrifugal backward fans, equipped with EC V8 motor technology up to 300 W, are suitable for ventilating and cooling this equipment.
Ø350 and 400mm axial fans: the ideal choice for high flow rates (up to 4,500 m3/h) at low pressure
Our 350 and 400 mm diameter models, combined with high-efficiency EC V8 motors, are suitable for computer room ventilation, air mixing, and hot air extraction in racks.
Thanks to EC technology, the rotation speed adapts precisely to actual cooling requirements. This allows for:
- a significant reduction in energy consumption,
- precise control of air flow,
- reduced noise thanks to optimized low-speed operation.
These EC axial fans are therefore particularly effective at maintaining a consistent temperature in cold aisles, while helping to improve data center efficiency.
Centrifugal backward fans Ø250 and 280 mm: performance and controlled pressure
Centrifugal backward fans, particularly those with diameters of 250 and 280 mm, are designed to provide an excellent compromise between flow rate and static pressure. They are ideal for applications requiring air to be circulated through obstacles such as filters, heat exchangers, cooling coils, or duct networks.
Equipped with EC V8 motors up to 300 W, these fans are used in:
- air conditioning units,
- data center air handling units (AHUs),
EC motors guarantee stable pressure, precise flow control, and reduced energy losses compared to traditional AC motors.
EC V8 technology adapted to the requirements of modern data centers
EC V8 technology stands out for its high efficiency, reliability in continuous operation, and ability to meet growing demands for energy efficiency and control (0-10VDC or PWM). Combined with Ø350 mm axial fans or Ø250 and 280 mm centrifugal fans, it provides a solution tailored to the current needs of data centers: better cooling, lower energy consumption, and more precise control. In short, our EC V8 ventilation solutions allow air to be moved where it is needed, with the right power, dynamically adapting to thermal loads, while contributing to the overall and sustainable performance of digital infrastructures.
Contact us during your design phase so that we can work with you to define the right ventilation solution for your needs.